DIAMOND

Models

    DIAMOND 40 K
    Model no. 170.4001.0
    Universal operating table with short back section and electrohydraulic adjustment by means of optional hand-held control unit of 4 table functions:
    - Raise/Lower
    - Lateral
    - Trendelenburg/Reverse Trendelenburg
    - Back section
    Additional adjustment of these functions by means of emergency handwheels and foot pump (hydraulic). Rechargeable batteries. Integrated battery charger with mains cable 230 V. Mobile on 4 double castors with central lock, 2 of which antistatic. 1 of the 4 castors with directional pedal, not retrofittable.
    Without head and leg plates, back section extension and hand control unit.

    Directional castor
    Model no. 101.0227.0
    additional spring-loaded fifth directional castor for DIAMOND OR tables, activated by dual-side foot pedal.

    Double table top
    Model no. 101.0430.0
    for X-ray cassette insertion, for DIAMOND OR tables with gyn. cutout and short back section (w/o ill.)

    Emergency control DIAMOND 40
    Model no. 101.0361.0
    detachable, cable-connected hand control for all adjustment functioins of the table acc. to its hand/foot control, attached to the table column

    DIAMOND 40 LK
    Model no. 170.4002.0
    Universal operating table with short back section and electrohydraulic adjustment by means of optional hand-held control unit of the table functions:
    - Raise/Lower
    - Lateral
    - Trendelenburg/Reverse Trendelenburg
    - Back section
    - Electro-hydraulic longitudinal shift function of table-top by totally 290 mm for optimal use of image intensifier.
    Additional adjustment of these functions by means of emergency handwheels and foot pump (hydraulic). Rechargeable batteries. Integrated battery charger with mains cable 230 V. Mobile on 4 double castors with central lock, 2 of which antistatic. 1 of the 4 castors with directional pedal, not retrofittable.
    Without head and leg plates, back section extension and hand control unit.

    Directional castor
    Model no. 101.0227.0
    additional spring-loaded fifth directional castor for DIAMOND OR tables, activated by dual-side foot pedal, not retrofittable.

    Double table top
    Model no. 101.0430.0
    for X-ray cassette insertion, for DIAMOND OR tables with gyn. cutout and short back section (w/o ill.)

    Emergency control DIAMOND 40
    Model no. 101.0361.0
    detachable, cable-connected hand control for all adjustment functioins of the table acc. to its hand/foot control, attached to the table column

    DIAMOND 50 BK
    Model no. 170.5500.0

    Universal operating table with short back section and electrohydraulic adjustment by means of (optional) hand-held control unit of 5 table functions:
    - Raise/Lower
    - Lateral
    - Trendelenburg/Reverse Trendelenburg
    - Back section
    - Leg section
    Additional adjustment of these functions by means of removable emergency control (electrohydraulic) or emergency handwheels and foot pump (hydraulic). Rechargeable batteries. Integrated battery charger with mains cable 230 V. Mobile on 4 double castors with central lock, 2 of which antistatic. 1 of the 4 castors with directional lock.
    Without head and leg plates, back section extension and hand control unit.

    Directional castor
    Model no. 101.0227.0
    additional spring-loaded fifth directional castor for DIAMOND OR tables, activated by dual-side foot pedal, not retrofittable.

    Double table top
    Model no. 101.0430.0
    for X-ray cassette insertion, for DIAMOND OR tables with gyn. cutout and short back section (w/o ill.)

    DIAMOND 60 BLK
    Model no. 170.6000.0

    Universal operating table with short back section and electrohydraulic adjustment by means of (optional) hand-held control unit of 6 table functions:
    - Raise/Lower
    - Lateral
    - Trendelenburg/Reverse Trendelenburg
    - Back section
    - Leg section
    - Electro-hydraulic longitudinal shift function of table-top by totally 290 mm for optimal use of image intensifier
    Additional adjustment of these functions by means of removable emergency control (electrohydraulic) or emergency handwheels and foot pump (hydraulic). Rechargeable batteries. Integrated battery charger with mains cable 230 V. Mobile on 4 double castors with central lock, 2 of which antistatic. 1 of the 4 castors with directional lock.
    Without head and leg plates, back section extension and hand control unit.

    Directional castor
    Model no. 101.0227.0
    additional spring-loaded fifth directional castor for DIAMOND OR tables, activated by dual-side foot pedal, not retrofittable.

    Double table top
    Model no. 101.0430.0
    for X-ray cassette insertion, for DIAMOND OR tables with gyn. cutout and short back section (w/o ill.)

    1
    2
    1. Head plate
      Model no. 101.0017.1

      double-adjustment, automatic latching of pad inclination, integrated gas spring for weight compensation, detachable.

      Double table top
      Model no. 101.0480.0
      for X-ray cassette insertion, for head plate 101.0017.1 (w/o ill.)
    2. Leg section
      Model no. 101.0116.1

      split type, fold-down, swivelling via latching mechanism, sealed against fluids, integrated gas spring for weight compensation, detachable, with carrying handles.
      Optionally without 45° cut-out.

      Double table top
      Model no. 101.0500.0
      for X-ray cassette insertion, for leg plate 101.0116.1 (w/o ill.)
    1
    2
    1. Leg section, four-part
      Model no. 101.0171.0
      part foldable down to 155°, swivelling via latching mechanism, detachable. A dual safety system for adjusting the leg plate prevents an accidental folding of the lower segment. The folding function can only be carried out after releasing the safety lever and triggering the safety handle.
      Optionally without 45° cut-out.

      Double table top
      Model no. 101.0540.0
      for X-ray cassette insertion, for leg plate 101.0171.0 (w/o ill.)
    2. Leg section
      Model no. 101.0145.1

      one-section type, manual folding with gas spring assistance, detachable.

      Double table top
      Model no. 101.0490.0
      for X-ray cassette insertion, for leg plate 101.0145.1 (w/o ill.)
    1
    2
    1. Back section extension, fixed
      Model no. 101.0131.0
      to be attached to the short back section, length 280 mm.

      Double table top
      Model no. 101.0510.0
      for X-ray cassette insertion, for for back section extension, fixed 101.0131.0 (w/o ill.)
    2. Back section extension, inclinable
      Model no. 101.0159.0
      to be attached to the short back section, for stretching patient‘s upper body in thoracic surgery and abdominal interventions, electromotive downward tilt up to 40°, length 300 mm including adapted pad for head section

      Double table top
      Model no. 101.0580.0
      for X-ray cassette insertion, for for back section extension, inclinable 101.0159.0 (w/o ill.)
      ×

      Can we help you?

      Contact

      We will be happy to provide you with further information about us and our products.